| Overview of released versions of Control Web 9 Each version of the Control Web system is
      kept up to date by actualizations during its whole active existence.
      These actualizations e.g. adjust the product to changes in newer
      versions of operating systems, extend functionality of separate
      components and also remove potential issues, found throughout the
      product's service life. | Control Web 9 Build 9.0.11 — released
          26. 9. 2025Bug fixes
                  Calling the SetYAxisPrecision(...) or
                  SetYAxisNumberFormat(...) procedures in the
                  data_viewer instrument could cause the system
                  to crash in some cases. The var parameters and the array
                  parameters of instrument data type and data
                  type were not passed correctly to the procedures.The instruments archiver,
                  alarm, journal and
                  trend incorrectly read the list of roles for
                  the access parameter in the file
                  section. Extensions
                  Export to XLSX format for
                  Excel has been added to the
                  InCalc program.The AddPathPoints( ObjectName : string; SubPathIndex : longcard; CountPoints : longcard; x, y : array of real ) : boolean
                  procedure has been added to the integrated drawing. Control Web 9 Build 9.0.10 — released
          29. 7. 2025Bug fixes
                  In the InCalc program, the
                  line style settings for frames were not respected in the
                  table. They were always drawn as solid.The SaveTableAs( FilePath : string; DecimalSeparator : any; Quote : boolean; UnixEOL : boolean ) : boolean
                  procedure did not work in the table
                  instrument.A bug causing incorrect identification of constants
                  has been fixed. Extensions
                  The GetRowsCount and GetColumnsCount
                  procedures has been added to the sheet
                  instrument.The GetXAxisAutoRange, SetXAxisAutoRange
                  procedures and label_element parameter has been
                  added to the graph instrument. Control Web 9 Build 9.0.9 — released 6.
          6. 2025Bug fixes
                  In virtual instrument gl_valve
                  procedure GetValue() : boolean did not work
                  .The xy charts were not working properly
                  in the data_viewer and chart
                  instruments.In the table instrument, the CreateImage(...)
                  and CreateGraph(...) procedures did not work
                  correctly when the object being created was inserted into a
                  layer other than the current one. Modifications
                  The indexing of archive database tables was optimized
                  when the application starts. ExtensionsControl Web 9 Build 9.0.8 — released
          16. 5. 2025Bug fixes
                  In the data_viewer legend, the Select
                  all series/Deselect all series command responded to all
                  unarchived data elements, including those that did not
                  belong to the current group.In the data_viewer and
                  gl_data_viewer instruments, in the data
                  element tree in the data_group section of the
                  instrument inspector and in the waveform parameter settings
                  window, the right mouse key to open the context menu did not
                  work correctly. In the data_viewer and
                  gl_data_viewer instruments, in the data
                  element tree in the waveform parameter setting window,
                  adding multidimensional array elements did not work
                  correctly.The web_server, json
                  and xml instruments could not be activated by
                  data change.If the VisionLab load the
                  image (as defined in the init_data section)
                  from the same directory where Control Web
                  stored the log files, freezing could occur when stopping the
                  application. Modifications
                  From this version, the sheet
                  instrument calls the OnStartup procedure after
                  the rows_count expression has been
                  evaluated.More efficient retrieval of data from the database
                  for displaying graphs in the data_viewer
                  required modification of the structure of the database
                  tables managed by the archive sections. The UTC_JD and
                  UTC_MSI items were added to the table and are now also used
                  as the primary key. The original UTC item has been retained,
                  for compatibility with possible user SQL
                  statements. ExtensionsControl Web 9 Build 9.0.7 — released
          25. 2. 2025Bug fixes
                  The procedures SetRealValue(...), SetBooleanValue(...)
                  and SetStringValue(...) in the
                  table instrument do not invalidate any
                  expressions originally placed in the cell being
                  overwritten.For gl_toggle_switch and
                  gl_button instruments, when placing them in
                  the panel, the behavior when pressing the mouse button over
                  the device and then releasing it outside the device area has
                  been changed. In this case, the click is not performed, as
                  is the case with other 2D instruments.Fixed incorrect loading of older ANSI application
                  texts caused by the 9.0.6 update. Extensions
                  For the meter virtual instrument, the
                  font can now be defined using OCL procedures.The transparent parameter has been added
                  to the string_display virtual instrument. The
                  instrument is then drawn without a background in panels with
                  a renderer other than GDI.The Text Editor adds support for block selection,
                  working with multiple cursors and the ability to set a dark
                  theme.Added axes_visibility_mode parameter to
                  trend and trend_viewer
                  instruments.To the trend and trend_viewer
                  instruments have been added methods:Source code tab added to the drawing
                  editor. Control Web 9 Build 9.0.6 — released
          17. 1. 2025Bug fixes
                  Procedure IsListOpened() in virtual
                  instrument string_switch works even if the
                  instrument has been blocked from editing strings by the
                  DisableEditable()procedure.The data_viewer in table
                  mode did not accept fonts from the application section
                  font ... end_font. Control Web 9 Build 9.0.5 — released
          13. 12. 2024Bug fixes
                  On some older Intel graphics adapters, the GL_ARB_imaging
                  extension is not supported in the graphics drivers. This led
                  to the inability to set subtractive color mixing for virtual
                  instruments with particle effects (fire, smoke, etc.) if the
                  instrument was on a light background. The instrument on a
                  light background could not be rendered with sufficient
                  contrast. On all other graphics adapters, everything always
                  worked without problems. The problem has been addressed and
                  resolved.On some older Intel graphics adapters, the operating
                  system sometimes fails to select the font used in the
                  current graphics rendering context. Then, some characters
                  are missing from the rendered text and the system may even
                  crash. This problem occurred very rarely. On all other
                  graphics adapters, everything always worked without
                  problems. The risk of this situation has been
                  addressed.The alarm_viewer instrument on the
                  client side of the network application in some cases (when
                  the application was started) incorrectly read the list of
                  active alarms. Extensions
                  The dimensions and mark_dimensions
                  parameters have been added to the
                  inner_caliper and
                  outer_caliper steps in VisionLab.For the web_server instrument, the
                  REST API has been extended to include login. If web login is
                  enabled in the instrument, authentication is now required
                  before using the REST API.  Control Web 9 Build 9.0.4 — released 9.
          12. 2024Bug fixes
                  The OnSetCursor() procedure was not
                  called in the db_view instrument if the time
                  cursor position was changed by a mouse click in the
                  chart.In the data_viewer instrument, the
                  filters for selecting the displayed data did not work
                  correctly in some cases.When manipulating table layers in the
                  Settings/Layer Settings... menu of
                  InCalc, the program may have
                  crashed.The LPAD and PROPER functions was not working
                  properly in the program InCalc.In db_view instrument, the Save(...)
                  method did not work in variants with a defined time interval
                  if the specified interval extended beyond the end of the
                  database.The SetGraphSampleInterval( FirstSample, LastSample : number )
                  method of the trend_viewer instrument was not
                  executed if the value of the LastSample
                  parameter was greater than the number of records in the
                  database. ModificationsExtensions
                  A right-click activated context menu has been added
                  to the db_view instrument legend to
                  enable/disable visibility for the entire group or for the
                  selected y-axis.Some graphics drivers for Intel and AMD do not have
                  the GL_ARB_imaging extension. In these cases,
                  the texture pixel mixing equation has been solved in an
                  alternative way. Control Web 9 Build 9.0.3 — released 5.
          11. 2024 | 
 |