Moravian instruments, Inc., source: https://www.mii.cz/art?id=295&lang=409, printed: 29.06.2026 4:10:04
| 16.6.2011 |
|---|
| Two new modules were added to the DataLab IO/USB industrial input/output system — digital counter module and incremental counter module. |
|
The DL-CNT1 module contains 4 counters with 24-bit range (numerical range of each counter is 0 to 16,777,215). The first two counters have more configuration options compared to the second couple of counters ():
Third and fourth counters functionality is limited to simple counting with the possibility to read and preset counter value. Counter modes (counting enable, logical signal levels etc.) are defined by software. The DL-CNT2 contains one incremental counter with 32-bit precision (counter numerical range is -2,147,483,648 to 2,147,483,647). The counter is also capable to preset counter value and capture value according to logical inputs and to signal alarm outputs if the counter value underflows low limit or overflows high limit. The counter can work in three modes:
Thorough module description can be found in the DataLab IO/USB hardware documentation. Software control and configuration options are described in the DataLab IO/USB Active X and Control Web driver documentation. Remark: The support for new counter modules is included in the DataLab IO/USB drivers (both 'dlusb.sys' system driver and 'dldrv.dll' Active X and Control Web driver) from version 1.6. It is necessary to upgrade to this version to work with counter modules. Drivers can be freely downloaded from our web site. |